Health & Medicinearticle2026-08-01

Assessment of left atrial native T1 values using non-contrast 3.0 T cardiac magnetic resonance imaging: a feasibility and reproducibility study

Open access0 citations

Abstract

Atrial cardiomyopathy (ATC) is characterized by structural and functional atrial remodeling and is associated with adverse cardiovascular outcomes. Native T1 mapping has emerged as a sensitive technique for tissue characterization; however, data on left atrial (LA) native T1 mapping remain limited. We evaluated the feasibility and reproducibility of LA T1 measurements using non-contrast 3.0-T cardiac magnetic resonance (CMR), thereby providing a methodological foundation for future studies of atrial tissue characterization. Healthy volunteers in sinus rhythm underwent non-contrast 3.0-T CMR, including native T1 mapping using a modified Look-Locker inversion recovery (5s(3s)3s MOLLI) sequence. LA native T1 values were measured in the 2-, 3-, and 4-chamber long-axis views. Two independent specialists measured LA native T1 values using regions of interest placed within the inner 2 reconstructed pixels of the LA wall to minimize in-plane partial volume effects. Feasibility was assessed by the proportion of measurable studies, and reproducibility by intra- and inter-observer intraclass correlation coefficients (ICC). Additional analyses were performed to assess potential blood-pool contamination. Forty volunteers (50% female; mean age 33.6 ± 6.1 years; body mass index of 22.7 ± 3.2 kg/m²) were included. LA native T1 values were measurable in 62.5%, 95.0%, and 75.0% of subjects in the 2-, 3-, and 4-chamber views, respectively, identifying the 3-chamber view as the most feasible imaging plane. Mean LA native T1 values were consistent across views (1,441–1,448 ms; all p > 0.05) without gender difference. Reproducibility was excellent, with intra-observer ICCs of 0.921–0.940 and inter-observer ICCs of 0.894–0.920. Agreement between views was good (ICC 0.709–0.878) without significant proportional bias. Blood-pool T1 values were substantially higher than LA T1 values (1,859–1,868 ms vs. 1,441–1,448 ms) and showed no significant correlation. Validation analyses demonstrated a progressive increase in blood-pool T1 values with increasing distance from the LA wall, supporting measurement specificity. Non-contrast T1 mapping enables feasible and highly reproducible quantification of LA native T1 values. The 3-chamber view demonstrated the highest measurability and may be the preferred imaging plane for LA tissue characterization. These findings provide a methodological framework for future investigations of ATC and other atrial diseases. Not applicable.

// Source

View paper (DOI)Open access versionOpenAlexBMC Medical ImagingPublished 2026-08-01

Authors: Nonthikorn Theerasuwipakorn, Nabhat Noparatkailas, Piyanun Sanguanwong, Sittinop Titichoatrattana, Rattanaporn Prasertdumrongchai, Yongkasem Vorasettakarnkij, Monravee Tumkosit, David C. Wendell, Pairoj Chattranukulchai

Institutions: Chiang Mai University, King Chulalongkorn Memorial Hospital, Chulalongkorn University, Duke Medical Center