Review examines wide-awake anesthesia for hand surgery and some fractures
The analysis found similar complication and revision rates, with shorter reported operating or perioperative times in included studies.
High evidenceReviewSome caution advised
Medical disclaimer: This article summarizes research findings and is for informational purposes only. It is not medical advice.
Editorial illustration — not from the study.
Researchers searched three medical databases for comparative studies published from 2018 through November 2025. They combined statistical results where possible and also summarized findings narratively, covering elective hand operations and selected acute upper-extremity fracture fixations.
The analysis found comparable functional outcomes across elective and acute procedures. WALANT was associated with a mean perioperative time that was 11.2 minutes shorter than the comparison approaches in the included studies, although the abstract does not identify all comparison methods or explain how consistently this outcome was measured.
What the review examined
The researchers asked whether the benefits reported for wide-awake local anesthesia without a tourniquet in elective hand surgery also appeared in selected upper-extremity fracture procedures. They conducted a PRISMA 2020 systematic review and meta-analysis of 16 comparative studies identified through PubMed, Embase, and the Cochrane Library. The review assessed complications, revision procedures, functional and patient-reported outcomes, and perioperative efficiency. Risk of bias was assessed with the RoB 2 and ROBINS-I tools. The abstract does not provide the total number of patients, the exact procedures in each group, or the full characteristics of the study populations.
Key conclusions
The pooled analysis found no statistically significant difference in complications: relative risk 0.37, with a 95% confidence interval from 0.12 to 1.16. It also found no statistically significant difference in revision procedures: relative risk 0.88, with a 95% confidence interval from 0.19 to 4.15. Functional outcomes were described as comparable across elective and acute procedures.
Perioperative efficiency favored WALANT, with a reported mean difference of 11.2 minutes shorter and a 95% confidence interval from 6.9 to 15.4 minutes shorter. The narrative and subgroup analyses indicated that findings seen in elective surgery were largely maintained in selected fracture-fixation procedures. These results describe associations across the included studies and do not show that WALANT itself caused the time differences or outcomes.
Who this is relevant to
These findings may be relevant to people undergoing procedures similar to those included in the comparative studies, particularly elective hand surgery and selected upper-extremity fracture fixation. They do not necessarily apply to every hand operation, every fracture, children, people with substantially different medical conditions, or settings with different surgical and anesthesia resources. The review does not provide enough information to determine applicability to any individual patient.
Why it matters
The review suggests that, in the selected operations and study populations examined, wide-awake local anesthesia may have similar measured complication, revision, and functional outcomes to comparison approaches while taking less perioperative time. This may be relevant to clinicians and health systems evaluating anesthesia options for certain hand and upper-extremity procedures. The evidence does not establish that the approach is suitable for all fracture repairs, all patients, or all surgical settings.
Limitations & evidence assessment
Only 16 comparative studies were included, and the abstract does not report their total sample size, detailed patient characteristics, follow-up duration, or individual study quality results. The fracture evidence involved selected acute procedures, so it may not represent more complex fractures or patients who were not included. Meta-analysis results can also be affected by differences among studies in procedures, comparison groups, outcome definitions, and follow-up. Some confidence intervals were wide, particularly for revision procedures, meaning the available data may be compatible with a range of effects. The abstract provides too little information to judge how consistent the results were across all studies.
Why this evidence level: Meta-analysis pooling multiple studies sits at the top of common evidence hierarchies.
Evidence levels are editorial estimates derived from study metadata — they are not clinical appraisals.
Researchers combined genetic data from more than 1 million human participants to study factors associated with endometriosis. They identified 58 genomic regions, including 27 not previously reported, and used additional molecular analyses to implicate 314 genes. These findings point to possible biological pathways for further research, but they do not establish causes or demonstrate that any treatment will work.
Researchers systematically reviewed laboratory studies of how temperature affects the time it takes arboviruses to become transmissible inside mosquitoes. Across 53 studies covering 17 viruses, higher temperatures were generally linked with greater transmission efficiency and a shorter time to infectiousness for Zika and West Nile viruses, while results for several other viruses were unclear.
This systematic review and meta-analysis examined whether ultra-low-dose computed tomography (CT) can detect pulmonary, or lung, nodules while using less radiation than standard-dose CT. Across 42 studies involving 15,792 patients, pooled sensitivity for nodule detection was 91.9%, but results varied greatly between studies. The review also found that ultra-low-dose CT used an average effective dose of 0.22 millisieverts (mSv), while detection was less reliable for some small or hazy nodules and in patients with a high body mass index.