Engineering & Technologyarticle2026-10-15

Instability-Aware Digital Twins for Robust Co-Optimization of Operational Carbon Emissions, Thermal Comfort, and Structural Serviceability Reliability under Uncertainty in Smart Buildings

Open access0 citations

Abstract

Modern smart buildings operate under continuously varying climatic, occupancy, equipment, grid-carbon, material, degradation, and sensing conditions, making nominal optimization insufficient for reliable operational decision-making. This study develops and numerically evaluates an instability-aware digital twin for robust co-optimization of operational carbon emissions, occupied-zone thermal discomfort, and component-level structural serviceability reliability under uncertainty. The framework combines a multi-rate thermal–energy–moisture–IAQ–structural model, carbon-aware CO₂-based ventilation control, extended Kalman filtering, Monte Carlo uncertainty propagation, FORM and design-point importance sampling, Gaussian-process surrogate modeling, NSGA-II, and dimensionless objective- and decision-instability metrics. A controlled six-zone benchmark represents a six-story office building with a gross floor area of 10,200 m² over a one-year operational horizon and a 20-year reliability horizon. Re-evaluation of the nominally selected P0 policy under the full modeled uncertainty set increased carbon emissions from 42.6 to 50.4 kgCO₂e m⁻² year⁻¹, occupied zone-time discomfort from 115 to 128 K h year⁻¹, and the serviceability limit-state exceedance probability from 0.021 to 0.031. The corresponding nominal-input underestimations were 15.5% for carbon and 32.3% for the exceedance probability. The selected robust policy produced 48.8 kgCO₂e m⁻² year⁻¹, 98 K h year⁻¹, and PSLS = 0.012, with a reliability index of 2.257. Relative to the uncertainty-aware P0 evaluation, it reduced carbon by 3.2%, discomfort by 23.4%, PSLS by 61.3%, and decision instability by 65.7%. The robust policy maintained a mean occupied zone-time CO₂ concentration of 684 ppm, a 99th percentile of 821 ppm, and zero occupied zone-hours above 1,000 ppm. Within the controlled numerical benchmark, the results show that Pareto efficiency alone does not establish operational robustness and that explicit instability quantification materially changes policy selection.

// Source

View paper (DOI)Open access versionOpenAlexResearch and Reviews in SustainabilityPublished 2026-10-15

Authors: Seyed Reza Samaei, Jarek Kurnitski, James Riffat

Institutions: Tallinn University of Technology, World Society of Sustainable Energy Technologies