Materials & Energyarticle2026-09-28

Assessment of selective flame-retardant transport to household dust from polymeric matrices

0 citations

Abstract

In this study, the migration behavior of three commercially relevant flame retardants—decabromodiphenyl ethane, tetrabromobisphenol A, and resorcinol bis(diphenyl phosphate)—was investigated in acrylonitrile–butadiene–styrene, polypropylene, and polycarbonate/acrylonitrile–butadiene–styrene matrices. Thermal stability, fire performance, blooming behavior, and dust transfer were evaluated using thermogravimetric analysis, Underwriters Laboratory (UL-94) vertical flame testing, ion chromatography, inductively coupled plasma optical emission spectroscopy, scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy, and diffusion modeling. All flame-retardant formulations achieved UL-94 V-0 classification, demonstrating effective fire performance relative to untreated controls. Reliable quantification by ion chromatography and inductively coupled plasma optical emission spectroscopy was achieved using compound-specific extraction and digestion procedures that demonstrated quantitative recovery of the target analytes. No measurable blooming was observed for acrylonitrile–butadiene–styrene + decabromodiphenyl ethane, acrylonitrile–butadiene–styrene + tetrabromobisphenol A, or polycarbonate/acrylonitrile–butadiene–styrene + resorcinol bis(diphenyl phosphate) during 30 days of accelerated aging at 70°C. In contrast, polypropylene + decabromodiphenyl ethane exhibited measurable surface migration, with bromine recoveries of 2.33 ± 0.01, 2.77 ± 0.33, and 0.72 ± 0.08 mg/cm 2 at days 1, 14, and 30, respectively. No measurable blooming was detected for any formulation during ambient aging at 25°C. The initial polypropylene + decabromodiphenyl ethane blooming regime was adequately described by Fick’s diffusion model, yielding an effective diffusion coefficient of 1.2 × 10 −13 m 2 /s. Measurable bromine transfer to settled dust was observed only for polypropylene + decabromodiphenyl ethane under accelerated aging (70°C), and reducing the dust loading from 60 to 30 g/m 2 resulted in an approximately 50-fold decrease in bromine concentration. Scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy confirmed the presence and spatial distribution of bromine within the collected dust but did not resolve the underlying transfer mechanism. Collectively, the results demonstrate formulation- and temperature-dependent differences in flame-retardant blooming and dust transfer and establish an association between measurable surface blooming and subsequent dust transfer under the conditions investigated.

// Source

View paper (DOI)OpenAlexJournal of Fire SciencesPublished 2026-09-28

Authors: Laura Fronchetti Guidugli, Owen Jappen, Joel Tenney, Gordon Nelson, M. Toufiq Reza

Institutions: Florida Institute of Technology, American Chemistry Council